Pressure network, not CFD
Each room is one well-mixed pressure zone. Results do not describe exact velocity,
turbulence, jets, recirculation, or comfort at points inside a room.
Default envelope and closed-door leakage values are illustrative and uncalibrated.
Exhaust replacement air comes only from modeled doors, supply fans, and visible
leakage.
Fan face dimensions do not determine airflow. Rated flow is required, output
percentage scales that rating, and the ideal fixed-flow model can demand more pressure
than a real fan can produce.
Door and fan elevation are saved and validated but do not affect pressure or flow in
this isothermal MVP. Results are not engineering, code-compliance, or life-safety
certification.
Door arrows show calculated link flow. Animated arrows inside rooms are qualitative
direction cues only; they are not local velocity vectors or CFD results.